Module i/o states, Power requirements, Physical characteristics – National Instruments NI WLS/ENET-9163 User Manual
Page 27: Antenna

© National Instruments Corporation
27
NI WLS/ENET-9163 Carrier User Guide and Specifications
Module I/O States
At power-on ........................................... Module-dependent. Refer to the
documentation included with the
C Series I/O module.
Power Requirements
Caution
You must use a National Electric Code (NEC) UL Listed Class 2 power supply
with NI WLS/ENET-9000 Series devices.
Note
Some C Series I/O modules have additional power requirements. For more
information about the C Series I/O module power requirements, refer to the documentation
included with the C Series I/O module.
Input voltage range................................. 9 V to 30 V
Maximum required input power ............ 4.5 W
Power input mating connector ............... 2 position combicon, Phoenix
Contact part number: 1714977
Physical Characteristics
Weight .................................................... Approx. 242 g (8.5 oz)
Weight with antenna
(NI WLS-9163 Only) ............................. Approx. 256 g (9 oz)
Dimensions............................................. 182 mm
× 95 mm × 37 mm
(7.18 in.
× 3.75 in. × 1.50 in.)
With rubber feet attached ....................... +3.56 mm (+0.140 in.)
Antenna
Antenna connector
(antenna not attached) ............................ +5.71 mm (+0.225 in.)
Attached, fully extended ........................ +108.7 mm (+4.28 in.)
Note
Refer to the