Paradyne 7976 User Manual
Page 7
7
7976-A2-GZ40-00
March 1999
Table 1.
Network Interface Options
Margin Threshold
Possible Settings: –5db, –4db, –3db, –2db, –1db, 0db, 1db, 2db, 3db, 4db, 5db, 6db,
7db, 8db, 9db, 10db
Default Setting: 0db
Determines the level, expressed in decibels, at which a signal-to-noise margin alarm
condition is reported.
Excessive Error Rate Threshold
Possible Settings: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9
Default Setting: 1E–6
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
AutoRate (LTU only)
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether the DSL line will automatically train up to the best rate or be user
selectable.
H
AutoRate is only available when the standalone unit is configured as an LTU.
DSL Line Rate
Possible Settings: 400, 528, 784, 1040, 1552, 2064
Default Setting: 2064
Specifies the DSL line rate of the unit.
H
DSL Line Rate is only available when the standalone unit is configured as an LTU
and AutoRate is disabled (unit is in fixed rate).
Peer IP Address (LTU Only)
Possible Settings: 000.000.000.001 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the peer IP address for the NTU, to provide remote management providing the
remote management link on the DSL loop.
H
Peer IP Address is only available when the standalone unit is configured as an
LTU.
Circuit Identifier
Possible Settings: [ASCII Text], Clear
Default Setting: [blank]
Uniquely identifies the circuit number of the transmission vendor’s DSL line for
troubleshooting purposes.