7976-A2-GZ40-00

March 1999

Switchpack Definitions

Manually change configuration options by moving Switchpack S1 DIP switches
on the card. Table 11 lists Switchpack S1 definitions.

Table 11.

Switchpack S1 Definitions

Switch # . . .

Allows you to . . .

Default in Bold

1

Enable or disable Switchpacks S1 and S2.

OFF = Switchpacks Disabled
ON = Switchpacks Enabled

2

Control line termination.

OFF = 120 Ohm
ON = 75 Ohm

3

Select the unit’s primary timing source. Only valid for units configured
as LTU.

OFF = Internal Clock
ON = External Clock

4

Control the unit’s E1 line coding.

OFF = HDB3
ON = AMI

5

Control the unit’s G.704 framing.

OFF = Framed
ON = Unframed

6

Enable CRC-4 monitoring. Only valid for units configured as LTU. The
NTU will automatically be configured to match the LTU setting.

OFF = Disable CRC-4 monitoring
ON = Enable CRC-4

7

Control whether Channel 16 contains signaling information or data.

OFF = Channel 16 is used for signaling
ON = Channel 16 is used for data

8

Not used