Functional modules, Functional modules -23 – Polycom DOC2237A User Manual
Page 95
MGC Hardware and Installation Manual
4-23
Functional Modules
The Functional Modules (cards) perform the various audio, video, and data
processing functions for the MGC unit. Both the MGC-100 and the MGC-50
use the same functional modules.
The MGC-100 unit houses up to sixteen Functional Modules, which can
occupy slots 1 through 16.
The MGC-50 unit houses up to eight Functional Modules, which can occupy
slots 1 through 8.
The LED’s on the front of each Functional Module indicate the status of
operation and whether it is functioning properly. Functional Modules are
installed via the front panel of the MGC unit. A connector at the rear of each
function al module connects the module to the backplane. Any module can be
inserted into any slot. All Functional Modules are front-removable and hot
swappable.
Table 4-4 lists the available Functional Modules.
Table 4-4: MGC Functional Modules Description
Functional Module
Function
Port capacity
Net-T1/Net-E1 ISDN
Network Interface
Interfaces between the MGC
unit and the ISDN network.
46 channels/60
channels
Net-2 ISDN/T1-CAS
Network Interface
Interfaces between the MGC
unit and the ISDN network or
T1-CAS lines.
46 channels/60 ISDN
channels or 48 T1-CAS
channels
Net-4 ISDN//T1-CAS
Network Interface
Interfaces between the MGC
unit and the ISDN network or
T1-CAS lines.
92 channels/120 ISDN
channels or 96 T1-CAS
channels
Net-8 ISDN/T1-CAS
and Net-8L ISDN
Network Interface
Interfaces between the MGC
unit and the ISDN network or
T1-CAS lines.
184 channels/240
ISDN channels or 192
T1-CAS channels
ATM-25 Network
Interface
Interfaces between the MGC
unit and the ATM network.
10 ports
ATM-155 Network
Interface
Interfaces between the MGC
unit and the ATM network.
20 ports