Chapter 4 - Hardware Description

4-42

MPI-8 Network Interface Data Stream

When the MCU is set as a DTE

The ISDN data stream flows from the ISDN telecommunication network
through the DCE to the serial port (37-pin connector) on the MPI box. The
data is then directed from the 37-PIN connector to the 160-PIN connector,
which gathers data from four different ports, and channels the data stream to
the 160-pin connector located on the MPI-8 front panel. The data is then
converted from serial format to TDM format and flown to the Backplane
information bus.

Since this is full duplex communication, the data is also flowing in the
opposite direction. Figure 4-22 shows the data flow on an ISDN data stream.

Figure 4-23: MPI Data Flow when MCU is DTE

The master and the Backup clock must be set on spans of the same network
type.

T1 ISDN line
(23 channels)

Channels 1-6

Channels

7-12

Ch

ann

els

13

-14

Ch

an

ne

ls

15

-1

6

Serial

connection

Serial

connection

37-PIN

connector

37-PIN

connector

160-PIN

connector

37-PIN

connector

37-PIN connector

To the 160-PIN connector

on the MPI-8 module

DCE