Paradyne 3161-B3 User Manual
Page 49
3. Operation
3160-A2-GB21-90
February 2001
3-15
The configuration options are divided into functional groups.
, contains a list of the configuration options and defaults.
These groups are:
T
DTE Interface Configuration Options
T
T
Network Interface Configuration Options
T
T
T
User Interface Configuration Options
T
T
Management Configuration Options
The DSU/CSU arrives with two preset factory default configuration settings. These
settings are based on the following:
T
Factory 1 – ESF framing format with B8ZS line coding format for both the
network and the DTE Drop/Insert (DSX-1) interfaces. Data ports are
unassigned.
T
Factory 2 – D4 framing format with AMI line coding format for both the
network and the DTE Drop/Insert (DSX-1) interfaces. Data ports are
unassigned.
If neither of the factory default settings support your network’s configuration, you
can customize the configuration options to better suit your application.
Use the Configuration (Cnfig) branch of the front panel menu tree to display or
change DSU/CSU configuration options (see