As shown in the figure below, each drive has three status LEDs.

Figure 5. Location of Drive Status Indicators (TX4 shown)

M

EANING OF

S

TATUS

I

NDICATORS

Indicator Color

Meaning

Power

Off

No disk drive power – power off or no disk installed.

Green

Disk power on.

Status Green Normal

Amber

Data is being rebuilt to this drive

Red

Failed

Disk

Off

No drive installed or the drive has failed

Green

This will blink on and off to indicate disk activity

C

RITICAL

& O

FFLINE

A

RRAYS

A fault tolerant array goes "critical" when a drive is removed or fails. Due to the
fault tolerance of the array, the data is still available and online. However, once
the array goes critical, the array has lost its fault tolerance, and performance may
be adversely affected. If the fault was caused by a drive that was removed, the
drive should be replaced by another drive, either identical or larger, in order for the
RAID system to rebuild and restore optimal configuration.