beautypg.com

Planet Technology GRT-101 User Manual

Page 65

background image

PLANET Technology Corp.

GRT-101/401 User

’s Manual

- -

60

list of applications and interfaces that provide status, enter:

admin# status ?

shdsl Show SHDSL status

wan Show WAN interface status

route Show routing table

To display specific information, for example, for the SHDSL interface status

and performance, enter:

admin# status shdsl

SHDSL mode

:SHDSL CPE Side

Bitrate

:512kbps

Tx Power

:13.5dBm

Current SNR Margin

:10.8dB

Attenuation

:35.8dB

CRC Error Count

:0

SHDSL Remote Side Status

Current SNR margin

:10dB

Attenuation

:35dB

CRC Error Count

:0

These statistics are:
• CRC error count — The cyclic redundancy check error count.
• Attenuation —The difference in decibels (dB) between the power level

received at the near end versus the power level transmitted from the far end.
• Signal-to-Noise (SNR) Margin — The SNR margin represents the amount of

increased received signal (in decibels) relative to the noise power level that the

unit is designed to tolerate without disconnecting from the network.

To display status of WAN ports, enter:

admin# status wan

WAN IP address / NetMask VPI/ VCI Enc Protocol Active

----- --------------- --------------- --- ----- ------ -------- ------

WAN1 192.168. 1. 1/255.255.255. 0 0/ 32 LLC IPoA Yes

To list active route status currently, type:

admin# status route