Tda5051a, Nxp semiconductors – Philips TDA5051A User Manual
Page 9
![background image](/manuals/184286/9/background.png)
TDA5051A
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 5 — 13 January 2011
9 of 29
NXP Semiconductors
TDA5051A
Home automation modem
[1]
The value of the total transmission mode current is the sum of I
DD(RX/TX)(tot)
+ I
DD(PAMP)
.
[2]
Frequency range corresponding to the EN50065-1 band. However, the modem can operate at any lower oscillator frequency.
[3]
The minimum value can be improved by using an external amplifier; see application diagrams
and
Reception mode
V
i(rms)
analog input signal
(RMS value)
82
-
122
dB
μV
V
I
DC level at pin RX_IN
-
2.5
-
V
Z
i
RX_IN input impedance
-
50
-
k
Ω
R
AGC
AGC range
-
36
-
dB
t
c(AGC)
AGC time constant
f
osc
= 8.48 MHz;
see
-
296
-
μs
t
d(dem)(su)
demodulation delay
set-up time
f
osc
= 8.48 MHz;
see
-
350
400
μs
t
d(dem)(h)
demodulation delay
hold time
f
osc
= 8.48 MHz;
see
-
420
470
μs
B
det
detection bandwidth
f
osc
= 8.48 MHz
-
3
-
kHz
BER
bit error rate
f
osc
= 8.48 MHz;
600 baud;
S/N = 35 dB;
signal 76 dB
μV;
see
-
1
-
1
× 10
−4
Power-up timing
t
d(pu)(TX)
delay between power-up
and DATA_IN in
transmission mode
XTAL = 8.48 MHz;
C1 = C2 = 27 pF;
R
p
= 2.2 M
Ω;
see
-
1
-
μs
t
d(pu)(RX)
delay between power-up
and DATA_OUT in
reception mode
XTAL = 8.48 MHz;
C1 = C2 = 27 pF;
R
p
= 2.2 M
Ω;
f
RXIN
= 132.5 kHz;
120 dB
μV sine wave;
see
-
1
-
μs
Power-down timing
t
d(pd)(TX)
delay between PD = 0 and
DATA_IN in transmission
mode
f
osc
= 8.48 MHz;
see
-
10
-
μs
t
d(pd)(RX)
delay between PD = 0 and
DATA_OUT in reception
mode
f
osc
= 8.48 MHz;
f
RXIN
= 132.5 kHz;
120 dB
μV sine wave;
see
-
500
-
μs
t
active(min)
minimum active time with
T = 10 ms power-down
period in reception mode
f
osc
= 8.48 MHz;
f
RXIN
= 132.5 kHz;
120 dB
μV sine wave;
see
-
1
-
μs
Table 5.
Characteristics
…continued
V
DDD
= V
DDA
= 5 V
±
5 %; T
amb
=
−
40
°
C to +85
°
C; V
DDD
connected to V
DDA
; DGND connected to AGND.
Symbol
Parameter
Conditions
Min
Typ
Max
Unit