Limiting values, Characteristics, Table 5 “characteristics – Philips TDA5051A User Manual
Page 7: Tda5051a, Nxp semiconductors
![background image](/manuals/184286/7/background.png)
TDA5051A
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 5 — 13 January 2011
7 of 29
NXP Semiconductors
TDA5051A
Home automation modem
9. Limiting
values
10. Characteristics
Table 4.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
Conditions
Min
Max
Unit
V
DD
supply voltage
4.5
5.5
V
f
osc
oscillator frequency
-
12
MHz
T
stg
storage temperature
−50
+150
°C
T
amb
ambient temperature
−50
+100
°C
T
j
junction temperature
-
125
°C
Table 5.
Characteristics
V
DDD
= V
DDA
= 5 V
±
5 %; T
amb
=
−
40
°
C to +85
°
C; V
DDD
connected to V
DDA
; DGND connected to AGND.
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
Supply
V
DD
supply voltage
4.75
5
5.25
V
I
DD(tot)
total supply current
f
osc
= 8.48 MHz
Reception mode
-
28
38
mA
Transmission
mode;
DATA_IN = 0;
Z
L
= 30
Ω
-
47
68
mA
Power-down mode
-
19
25
mA
I
DD(RX/TX)(tot)
total analog + digital
supply current
V
DD
= 5 V
± 5 %;
Transmission or
Reception mode
-
28
38
mA
I
DD(PD)(tot)
total analog + digital
supply current
V
DD
= 5 V
± 5 %;
PD = HIGH;
Power-down mode
-
19
25
mA
I
DD(PAMP)
power amplifier
supply current
V
DD
= 5 V
± 5 %;
Z
L
= 30
Ω;
DATA_IN = LOW in
Transmission mode
-
19
30
mA
I
DD(PAMP)(max)
maximum power amplifier
supply current
V
DD
= 5 V
± 5 %;
Z
L
= 1
Ω;
DATA_IN = LOW in
Transmission mode
-
76
-
mA
DATA_IN and PD inputs; DATA_OUT and CLK_OUT outputs
V
IH
HIGH-level input voltage
0.2V
DD
+ 0.9
-
V
DD
+ 0.5
V
V
IL
LOW-level input voltage
−0.5
-
0.2V
DD
− 0.1
V
V
OH
HIGH-level output voltage
I
OH
=
−1.6 mA
2.4
-
-
V
V
OL
LOW-level output voltage
I
OL
= 1.6 mA
-
-
0.45
V