Planet Technology VIP-110 User Manual
Page 38
Telephony Interface Port Configuration Commands
26
Related Commands
set port port cid name
set port port cid number
set port_cfg fxs cpc_dur
The ITG implements loop current shutdown feature on FXS port. It shuts down the current
feeding toward a FXS port upon detecting a call is being terminated by the other party
participated in the call. This command is used to set the duration, in milliseconds, of the loop
current shutdown (CPC supervisory disconnect).
set port_cfg fxs cpc_dur milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 1 to 60000. 0 stands for never
shutting down loop current
Factory default
0
set port_cfg fxs cpc_wait
This command is used to set the time to wait, in milliseconds, after a FXS port shutting down
loop current and before checking for on-hook.
set port_cfg fxs cpc_wait milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 1 to 60000.
Factory default
20
set port_cfg fxs ff_batt_rev
If a call is originated from a FXS port, the ITG may be optionally reverse the DC voltage
applied to the tip and ring signal of the FXS port after the called party off-hook the called port.
This command is used to enable this option.
set port_cfg fxs ff_batt_rev {on | off}
Syntax description
on
Enable battery reverse option for FXS port
off
Disable battery reverse option for FXS port
Factory default
off