Telephony Interface Port Configuration Commands
20
port#
Zero-based number of the telephony port.
number
Caller ID number, 1 to 15 digits.
O
Call ID is number is not available
Factory default
No caller ID number
set port port# default
This command sets all the port-unique parameters to factory default values.
set port port# default
Syntax description
port#
Zero-based number of the telephony port.
set port port# dial_in plar
This command is used to configure the number to be dialed in automatically (automatic
ring-down) when a telephony port goes off-hook. If no number is entered, operation will be as
normal.
set port port# dial_in plar number
Syntax description
port#
Zero-based number of the telephony port.
number
The phone number to be dialed automatically upon detecting
off-hook.
Factory default
None
set port port# port_cfg
The ITG maintains two sets of port-common parameter. This command is used to select which
set of the port-common parameters is to be used by a telephony interface port.
set port port# port_cfg {pri | sec}
Syntax description
port#
Zero-based number of the telephony port.
pri
Use primary port-common parameters
sec
Use secondary port-common parameters
Factory default
Primary