14.0

Fault Finding

Fault Finding Solutions

Is there 230V at:

Is there 230V at:

Main terminals L and N

Check electrical supply

1.

NO

Main terminal fuse

Replace fuse

Replace main PCB

neon

illuminated

2.

YES

Selector terminals a & b and a
& 3. PCB - A4 connector
terminals 4 & 5

Check wiring
Replace selector

3.

NO

NO

A

Pump

Replace pump

1.

YES

PCB - A4 connector terminals

Replace main PCB

2.

NO

Change pump supply cable

YES

B

CH system pressure 0.5 to 1.5 bar

Re-pressurise system

1.

NO

Primary flow valve diaphragm damaged

Replace diaphragm

Flow valve rod obstructed - clean, reset

3.

YES

Check automatic air vent is open

Open the automatic air vent

2.

NO

NO

C

YES

Continuity across flow
microswitch and PCB - A5
connector terminals 7 & 8

Replace microswitch

1.

NO

NO

Temperature sensor faulty.
Cold resistance approx. 11 kΩ
(resistance reduces with increase in temp.)

Replace sensor

2.

YES

Fan connections correct at fan. PCB
- A2 connector 230V across
terminals 5 & 7

Fan jammed or faulty winding

Replace main PCB

Replace fan

YES

3.

D

If pump jammed, release

NO