0 fault finding – Baxi Potterton 80 HE User Manual

Page 43

background image

43

14.0

Fault Finding

Domestic Hot Water - Follow operational sequence

Primary flow switch operated

Fan runs at max speed.

Pump runs

Turn preheat control to on.

Preheating function starts after

25 seconds.

neon flashing.

Primary water is diverted from

preheating circuit to DHW

heat exchanger.

neon illuminated

Air pressure switch proved.

neon flashing

Spark at ignition electrode for

up to 10 seconds.

neon flashing

Go to section ‘B’

neon flashing

Go to section ‘C’

neons flashing

Go to section ‘D’

neon flashing

Go to section ‘I’ & ‘N’.

Turn the selector to reset.

If regular resetting is required

or appliance still does not

operate investigation is

necessary.

neon flashing

Go to section ‘E’

YES

YES

YES

NO

Turn On/Off/Reset selector to

position.

neon illuminated.

Primary water diverted to

DHW preheating circuit.

Open DHW tap fully. DHW

flow switch operated.

Burner lights.

Burner output modulates to

maintain temperature set at

preheat control.

Burner goes out.

Burner extinguishes after 10

seconds.

NO

Close DHW tap.

DHW flow valve senses no

flow. DHW flow switch

released off.

Preheating function restarts.

neon flashing

Go to section ‘A’.

Go to section ‘M’.

External controls and where

fitted, integral timer calling for

heat.

Go to section ‘L’.

Ensure controls are set to

demand and verify the contacts

are closed.

DHW flow rate more than 2.5

l/min.

Is mains water filter and

differential assembly clean?

DHW flow valve diaphragm

damaged.

Replace diaphragm.

DHW flow valve rod

obstructed.

Continuity across DHW flow

microswitch terminals and PCB
- A5 connector terminals 5 & 6

Replace DHW flow

microswitch.

Replace main PCB

Go to section ‘J’ or ‘O’.

Turn selector to the reset

position. If the neon does not

extinguish go to sections H and

K.

Change main PCB.

Go to section ‘F’.

Reduce the DHW flow rate. If

burner does not modulate

clean DHW temperature

sensor and DHW heat

exchanger. If modulation does

not occur go to section ‘G’.

External controls and where

fitted, integral timer calling for

heat.

Fan stops.

Pump continues to

run for 30 seconds.

Operation sequence

correct

Ensure controls are set to

demand and verify the controls

are closed.

Go to section ‘L’.

YES

NO

NO

YES

NO

NO

YES

YES

YES

YES

YES

NO

NO

YES

YES

NO

NO

YES

YES

NO

YES

NO

NO

YES

NO

NO

YES

YES

NO

NO

YES

YES

YES

NO

YES

YES

YES

YES

YES

neon flashing

NO

YES

NO