beautypg.com

Panasonic CR Relays User Manual

Page 4

background image

CR

For Cautions for Use, see Relay Technical Information.

9-(1). Electrical life test (Motor free)

Sample: CR2-12V, 3pcs
Load: Inrush current: 25A, Steady current: 6A,
Brake current: 15A,
power window motor actual load (free condition)
Tested voltage: 14V DC
Ambient temperature: Room temperature

Circuit

Change of pick-up and drop-out voltage

Change of contact resistance

14VDC

M

0

No. of operations,

× 10

4

Pick-up and drop-out voltage, V

Max.

Max.

Min.

Min.

X

X

2

1

4

6

8

9

7

5

3

10

0

20

10

Pick-up voltage

Drop-out voltage

Max.

Min.

X(N.C.)

0

No. of operations,

× 10

4

Contact resistance, m

Max.

Min.

X(N.O.)

50

40

30

20

10

0

10

N.O. side

N.C. side

Load current waveform

Inrush current: 25A, Steady current: 6A,
Brake current: 15A
Tested voltage: 14V DC

100ms

10A

9-(2). Electrical life test (Motor lock)

Sample: CR2-12V, 3pcs
Brake current: 22A,
power window motor actual load (lock condition)
Tested voltage: 14V DC
Switching frequency: (ON:OFF = 0.5s:9.5s)
Ambient temperature: Room temperature

Circuit

Change of pick-up and drop-out voltage

Change of contact resistance

14VDC

Motor

M

0

No. of operations,

× 10

4

Pick-up and drop-out voltage, V

Max.

Max.

Min.

Min.

X

X

2

1

4

6

8

9

7

5

3

10

0

10

5

Pick-up voltage

Drop-out voltage

0

No. of operations,

× 10

4

Contact resistance, m

Max.

Min.

X

10

20

30

40

50

0

10

5

Max.

Min.

X

N.O. side

N.C. side

Load current waveform

Brake current: 22A
Tested voltage: 14V DC

100ms

5A