Installation, Work flow, Before installation – Panasonic WR-XS3P User Manual

Page 11: Work flow ■ before installation, Power connection, Installation place, Rack mounting, Grounding the unit, Condenser microphone

background image

11

System Configuration

Decide what kind of system to form. Determine the num-
ber of the external devices, the connection form, and the
mode (p. 14 Unit Modes and Signal Flow).

d

Connections

Connect the components to the unit.

d

Settings

Configure the following settings:

• Modes (pp. 14 to 17)
• Input line assignment (if using the SUB OUT jack) (p.

18)

• Output line assignment to MULTI IN/LINE IN.(p. 19)

d

Sticking a Label (p. 26)

Stick the supplied label on each component.

d

Adjusting the Input and Output Levels (pp. 29 to 31)

Adjust the input and output levels with the knobs on the
front panel.

d

Attaching/detaching the acrylic cover (p. 28)

Attach the acrylic cover on the unit front panel to prevent
wrong operation.

INSTALLATION

Work Flow

Before Installation

Caution:

Contact your dealer for installing the unit.
Be sure to toggle the power off and unplug the unit from
the receptacle before installation. Follow the safety
instructions.

Power Connection

Connect the power cord by any of the following methods,
making sure to provide a breaking device in each case.

(1) Connect the power cord to the power control unit.
(2) Install the unit near a receptacle and connect the power

cord to the receptacle via a breaking device. The
breaking device should be installed near an operator.

(3) Connect the power cord to a circuit breaker in a panel

board that has a contact distance of 3.0 mm or more.
Use a circuit breaker that will interrupt each circuit of
the main power supply (except a ground-protective
conductor).

Installation Place

• Install the unit out of direct sunlight and away from out-

lets of heated air. Installation in a humid, dusty or shaky
place may cause trouble.

• Keep a distance between this unit and a transformer,

dimmer, image device, CRT monitor, etc. as much as
possible. Failure to do this may cause induction noise.

Rack Mounting

Keep the temperature in the rack below 45 °C . Failure to
do this may cause damage to internal components.

Grounding the Unit

Ground the unit by the grounding terminal at the rear side.
If the devices are connected in unbalanced connections,
synchronize each grounding potential as follows:

• Synchronize the power supply phases.
• Synchronize the power supply lines.
• Connect each device's grounding terminal or chassis

with a thick grounding wire of each device.

Failure to do this may cause induction noise.

Note:

If the unit is placed more than 10 m away from

other external devices, grounding the unit near an unbal-
anced external device is recommended.

Condenser Microphone

• When using a condenser microphone, connect it to an

external device.

• Do not connect external devices supplying phantom

power, as it may damage the unit.