System Configuration
Decide what kind of system to form. Determine the num-
ber of the external devices, the connection form, and the
mode (p. 14 Unit Modes and Signal Flow).
d
Connections
Connect the components to the unit.
d
Settings
Configure the following settings:
• Modes (pp. 14 to 17)
• Input line assignment (if using the SUB OUT jack) (p.
18)
• Output line assignment to MULTI IN/LINE IN.(p. 19)
d
Sticking a Label (p. 26)
Stick the supplied label on each component.
d
Adjusting the Input and Output Levels (pp. 29 to 31)
Adjust the input and output levels with the knobs on the
front panel.
d
Attaching/detaching the acrylic cover (p. 28)
Attach the acrylic cover on the unit front panel to prevent
wrong operation.
INSTALLATION
■
Work Flow
■
Before Installation
Caution:
Contact your dealer for installing the unit.
Be sure to toggle the power off and unplug the unit from
the receptacle before installation. Follow the safety
instructions.
●
Power Connection
Connect the power cord by any of the following methods,
making sure to provide a breaking device in each case.
(1) Connect the power cord to the power control unit.
(2) Install the unit near a receptacle and connect the power
cord to the receptacle via a breaking device. The
breaking device should be installed near an operator.
(3) Connect the power cord to a circuit breaker in a panel
board that has a contact distance of 3.0 mm or more.
Use a circuit breaker that will interrupt each circuit of
the main power supply (except a ground-protective
conductor).
●
Installation Place
• Install the unit out of direct sunlight and away from out-
lets of heated air. Installation in a humid, dusty or shaky
place may cause trouble.
• Keep a distance between this unit and a transformer,
dimmer, image device, CRT monitor, etc. as much as
possible. Failure to do this may cause induction noise.
●
Rack Mounting
Keep the temperature in the rack below 45 °C . Failure to
do this may cause damage to internal components.
●
Grounding the Unit
Ground the unit by the grounding terminal at the rear side.
If the devices are connected in unbalanced connections,
synchronize each grounding potential as follows:
• Synchronize the power supply phases.
• Synchronize the power supply lines.
• Connect each device's grounding terminal or chassis
with a thick grounding wire of each device.
Failure to do this may cause induction noise.
Note:
If the unit is placed more than 10 m away from
other external devices, grounding the unit near an unbal-
anced external device is recommended.
●
Condenser Microphone
• When using a condenser microphone, connect it to an
external device.
• Do not connect external devices supplying phantom
power, as it may damage the unit.