Installing the power cables—AC units
This section describes installing the power cables into the IEC-320 connectors on the IpChannel Bank. Do not
connect the remaining end of the power cables to the power outlet at this time. Do the following:

1. Install the power cable into an IEC-320 connector (see

figure 11

on page 32). The AC mains socket outlet

shall be within 1 foot (3 meters) of the equipment and shall be easily accessible.

2. Rotate the power cable retainer clip so it secures the power cable plug in the IEC-320 connector as shown

in

figure 12

.

Figure 12. Grounding stud and power cable retainer clip

Mains Voltage: Do not open the case when either power cord is attached. The
SmartNode router is equipped with dual power supplies. Disconnect both
power supply cords before servicing. For systems without a power switch,
line voltages are present within the power supply when the power cords are
connected. The mains outlet that is utilized to power the SmartNode router
shall be within 10 feet (3 meters) of the device, shall be easily accessible, and
protected by a circuit breaker.

The Model SN4900 is not shipped with power cables. For AC powered units,
ensure that the power cable used meets all applicable standards for the coun-
try in which it is to be installed, and that it is connected to a wall outlet which
has earth ground.

The Model SN4900 can only be configured with two AC power
supplies or two DC supplies, you cannot mix AC and DC sup-
plies in the same chassis.

The router power supply automatically adjusts to accept an input
voltage from 100 to 240 VAC(50/60 Hz).

WARNING

WARNING

CAUTION

IMPORTANT

Power cable

retainer clip

Grounding stud