beautypg.com

Replacement, English – Panasonic TQBJ0349 User Manual

Page 79

background image

Replacement

ENGLISH -

79

Maintenance

Use a Phillips screwdriver to loosen

4 )

the “Lamp unit cover fixing screw”

(3 screws) for the lamp unit to be

replaced until the screws turn freely.

Hold the “Handle” of the “Lamp unit”

and gently pull the lamp unit out from

the projector.

Replace the new LAMP unit in correct

5 )

direction.

Use a Phillips screwdriver to securely

6 )

tighten the 2 “Lamp Unit cover fixing

screw” for lamp unit.

Note

When the lamp unit is replaced, the duration of usage

z

time will be reset to “0”.

Open the “Exhaust Fan” as illustrated,

7 )

and remove the “Air Filter” from “Air

filter housing".

Mount a new “Air Filter” in the

8 )

“Air Filter housing”, and close the

“Exhaust Fan".
Close the “Exhaust Fan” cover in the

9 )

reverse procedure of Step (3). Then,

tighten and secure the “Exhaust

fan fixing screw” (1 piece) using a

Phillips-head screwdriver.
Mount the “Air Filter/Lamp Unit

10 )

cover", and retighten "Air Filter/Lamp

Unit cover fixing screw" (1 piece) of

this cover securely.

Handle

Lamp unit fixing screws

Lamp unit installation

guide

Groove for lamp unit

installation guide

Handle

Air filter

Air filter housing

This manual is related to the following products: