Diagnostic Error Code
FRU/Action
175-199-XXX Thermal Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 67
2. Flash the system and re-test. See “Flash update
3. Replace component under function test
175-250-XXX 175-251-XXX Thermal Sensor(s) limit error
1. Check fans
2. Check Power supply voltages
3. Microprocessor
4. System board
185-000-XXX Asset Security Test Passed
No action
185-XXX-XXX Asset Security failure
1. Flash system
2. System board
185-278-XXX Asset Security Chassis Intrusion
1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX System Memory Test Passed
No action
201-XXX-XXX System Memory error
1. Replace the memory module called out by the test
2. System board
202-000-XXX System Cache Test Passed
No action
202-XXX-XXX System Cache error
1. Cache, if removable
2. System board
3. Microprocessor
206-000-XXX Diskette Drive Test Passed
No action
206-XXX-XXX Diskette Drive error
1. Diskette Drive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
215-000-XXX CD-ROM Drive Test Passed
No action
215-XXX-XXX CD-ROM Drive error
1. CD-ROM Drive Cable
2. Check power supply voltages
3. CD-ROM drive
4. System board
217-000-XXX Hard Disk Drive Test Passed
No action
217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error
1. Hard Disk Drive Cable
2. Check power supply voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (IDE)
5. System board
62
Hardware Maintenance Manual Lenovo 3000 J Series