beautypg.com

Lenovo J SERIES 3000 User Manual

Page 66

background image

Diagnostic Error Code

FRU/Action

086-197-XXX Mouse Port interface test warning

1. Make sure the component that is called out

is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

086-198-XXX Mouse Port interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Go to “Undetermined problems” on page 67

086-199-XXX Mouse Port interface test failed, cause
unknown

1. See “Undetermined problems” on page 67

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Replace component under function test

089-000-XXX Microprocessor Test Passed

No action

089-XXX-XXX Microprocessor failure

1. Microprocessor(s)

2. System board

089-195-XXX Microprocessor Test aborted by user

Information only Re-start the test, if necessary

089-196-XXX Microprocessor test halt, error threshold
exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

089-197-XXX Microprocessor test warning

1. Make sure the component that is called out

is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

089-198-XXX Microprocessor test aborted

1. Flash the system. See “Flash update procedures”

on page 185

2. Go to “Undetermined problems” on page 67

089-199-XXX Microprocessor test failed, cause unknown

1. See “Undetermined problems” on page 67

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Replace component under function test

170-000-XXX Voltage Sensor(s) Test Passed

No action

170-0XX-XXX Voltage Sensor(s) failure

1. Flash system

2. System board

170-195-XXX Voltage Sensor(s) Test aborted by user

Information only Re-start the test, if necessary

60

Hardware Maintenance Manual Lenovo 3000 J Series