Lenovo J SERIES 3000 User Manual
Page 63
Diagnostic Error Code
FRU/Action
030-03X-XXX 030-04X-XXX SCSI interface error
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-195-XXX SCSI interface Test aborted by user
Information only Re-start the test, if necessary
030-196-XXX SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
030-197-XXX SCSI interface test warning
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
030-198-XXX SCSI interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41
2. Flash the system and re-test. See “Flash update
3. Go to “Undetermined problems” on page 67
030-199-XXX SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page 67
2. Flash the system and re-test. See “Flash update
3. Replace component under function test
035-000-XXX RAID interface Test Passed
No action
035-0XX-XXX RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX RAID interface Test aborted by user
Information only Re-start the test, if necessary
035-196-XXX RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
035-197-XXX RAID interface test warning
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
Chapter 7
.
Symptom-to-FRU Index
57