NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Thermostat Installation:
Note:
Always Disconnect Power Before Performing The Thermostat

Installation.

A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included

in the accessory package. It is recommended that the thermostat and

thermostat wire be installed by an Lennox Hearth Products dealer.

Installation Steps:

1. Unplug stove power cord from the wall outlet.

2. Locate the thermostat terminal block (see Figures 7 and 8).

3. Loosen the two terminal screws on the terminal block and remove the

jumper.

4. Connect the two wires from your thermostat to the terminals (one

per terminal). Ensure that the purple wires from the harness remain

connected to the terminal block and tighten the terminal screws. Make

sure the wires are firmly connected to the thermostat.

5. Plug in the stove and you are ready to operate with your thermo-

stat!

Figure 6 - Damper Adjustment

Damper

Loosen Setscrew

to Adjust Damper

Firebox

Standard Setting: Damper

should be flush with

firebox as shown

Prior to lighting your appliance:

q

Review the safety precautions section.

q

Review the pellet FUEL section.

q

Review and follow the Operating Instructions.

q

Plug power cord connector into corresponding connector on the back

of appliance (see Figures 7 and 8 showing connector locations).

After you have begun operation of your appliance:

q

Review the routine cleaning / maintenance information.

q

Enjoy the warmth from your new Lennox Hearth Products pellet

stove!

Damper Location and Adjustment

Damper Air Control

Located behind the right side panel on model Montage 32FS.

Adjustment Procedure

Using a 1/4" nut driver or socket, loosen the damper setscrew (see

Figure 6). Adjust in 1/4” increments until optimum combustion air flow

is achieved. Retighten the damper setscrew.

For less air push in and for more air pull out.

Thermostat wires and purple wires from wire har-

ness will connect to these terminals

Figure 7 - Terminal Block

Remove jumper if Thermostat IS to be used

Leave jumper on, if thermostat is NOT used

Figure 8 - Terminal Block Location

Jumper

Route thermostat wires

through this grommet

IMPORTANT NOTE: Install the thermostat per the manufacturers instruc-

tions, provided with the thermostat. Failure to follow manufacturers

instructions could result in a malfunction. Pay special attention to the

thermostat location requirements. If the location requirements are not

adhered to the appliance, erratic operation or failure may occur.

Do not mount the thermostat where it may be affected by:

• Radiant heat from the stove, fireplaces, sun or other heat sources.

• Drafts or dead spots behind doors or in corners.

• Hot or cold air from ducts.

Note: See Wiring Diagram on Page 28.

IMPORTANT

If the wall thermostat provided is not used, the