Pre-lighting Instructions

During an initial start-up, or in the case where the hopper has run out of

fuel, it will be necessary to prime the auger feed system.

To prime the auger feed system:

1. Fill the hopper with recommended pellet fuel and plug the stove into

the wall outlet.

2. Press the "START" button on the control board to start the fuel feed.

Next, press the "HEAT OUTPUT" button to position #5 (maximum feed

rate).

3. Look through the combustion chamber door and when you see the first

pellets dropping into the UltraGrate™, the auger is then fully primed.

It will take 10 to 15 minutes to prime the auger.

4. Once the auger is primed, press the "STOP" button to turn off the auger

(LED will go off).

Starting Your Pellet Stove

1. Make sure the auger is primed (see Pre-Lighting Instructions on this

page), then simply push the "START" button on the control board to

activate the Fastfire™ igniter.

2. While the pellets will ignite on any heat output setting, it is recommended

that the "HEAT OUTPUT" button be set to position #3. Pellets will start

feeding into the UltraGrate and should begin to ignite in approximately

three to seven minutes. The Fastfire igniter will automatically shut off

after 8 minutes.

3. After the pellets are burning well, press the "HEAT OUTPUT" selector

to the desired setting. Combustion air and the pellet fuel feed rate will

adjust automatically as the "HEAT OUTPUT" button is pressed. The

flame should be bright yellow in color and there should be no evidence

of soot formation at the top of the flame. Press the "BLOWER" speed

button to increase or decrease the blower speed to the desired level

4. If operating your stove with the wall thermostat, adjust the "HEAT

OUTPUT" button to the desired demand mode (#1 through #5 on the

"HEAT OUTPUT" button). Next, adjust the wall mounted thermostat

to the desired room temperature and your stove will automatically

switch between a demand mode and stand-by mode.

Notes:

Cold Start - When the "START" button is pressed when the appliance

is cold, voltage will bypass its normal circuit through the low limit

thermal switch (for 20 minutes to allow adequate time for the low limit

thermal switch to heat [140° F min.] which will close the circuit). The

combustion and convection blowers will start at maximum speed.

After approximately 10 seconds both blowers will default to settings

they were at after the last shut down was completed (indicated by

LED's #1 to #5). The Fastfire igniter will operate for approximately 8

minutes. The auger will turn continuously for a predetermined dura-

tion at the respective Heat Output Settings, followed by the normal

operating mode.

Re-Fueling While in Operation

1. Open hopper lid and fill hopper with pellets.

2. Make sure the hopper lid is completely closed.

3. Check to make sure the stove remains lit.

4. If the flame goes out, press the "start" button on the control panel to

re-ignite.

Caution: Failure to ensure pellets in the UltraGrate remain

burning after re-fueling may result in smoke escaping from

the unit.

General Operating Considerations

Proper Burn Characteristics: Your flame should be bright yellow under

normal operations. If your flame becomes reddish/orange, your stove

probably needs routine maintenance. Excessive amounts of fly-ash build-

up in the UltraGrate, clinkers in the UltraGrate, or leakage of air if the

UltraGrate is not properly seated, will starve the fire for air. (See Routine

Maintenance for information on cleaning the stove). If the problem per-

sists, review the troubleshooting section at the end of this manual.

Manual and Automatic Operation

Your pellet stove can be operated in either the manual or automatic mode.

The manual mode is used when operating without a wall thermostat. The

automatic mode is used when utilizing a wall thermostat. When utilizing the

thermostat capability, the burn time can be extended dramatically depending

on thermostat setting. Note: It is normal for some ash to build up on the

inner glass surface at the lower Heat Output settings.

Manual Operation

Pressing the "START" button will initiate the start-up cycle. The auger

LED will be green to indicate the “on” status. The blower speeds and

pellet feeds are fixed during this time to provide appropriate ignition.

The Fastfire igniter system will light the pellets fed to the UltraGrate, after

about 3 minutes. After the start-up cycle, your stove will be in the run

mode. At this point the stove will operate with the heat output ("HEAT

OUTPUT" button) and blower settings ("BLOWER" button) selected. These

settings can be selected either during or after the start-up cycle. Pressing

the "STOP" button during the run mode will initiate the shut down cycle

(feeding LED will go off). The pellets will stop feeding and the blowers

will run at a fixed speed for approximately 10 minutes. At this point your

stove is safely shut down. The stove can be restarted by pressing the

"START" button during the shut down cycle.

Automatic Operation

Your stove is capable of running in an automatic mode with the use of

a wall thermostat.

For the wall thermostat to control the operation of the stove, set it to a

temperature that will put it in the demand mode (calling for heat). The

thermostat will establish either a demand mode or a stand-by mode.

The thermostat should be set for the desired room temperature. If the

room temperature drops below the level on the thermostat the stove

will automatically begin the start-up cycle, as explained in the Manual

Operation section.

Once the start-up cycle is completed the stove will operate at whatever

heat and blower setting you have selected. For best operation under

thermostat control, the medium or high settings are recommended. When

the desired room temperature is reached the stove will automatically go

into the shut down cycle. The pellet feed will stop and the blowers will

continue for a controlled time allowing safe shut down of your stove. All

lights will remain on when the thermostat is open. The "HEAT OUTPUT"

and "BLOWER" settings can be changed at any time, but only take affect

during the run mode. When the temperature in the room drops to the

level set at the thermostat, the stove will again begin the start-up cycle

and resume automatic operation in the demand mode.

Note: If the "START" button is pressed while the thermostat is in the

standby mode the stove will not restart until the thermostat closes (call-

ing for heat).