Wall Straps

Required Every

4 Feet Minimum

Standard Vertical Installation Configurations
Model: Montage™ 3FS

This free-standing model may be connected to an existing flue or by

installing listed type “PL” vent pipe. If a liner is run all the way to the

top of the existing chimney, the existing flue should be sealed with a

steel plate. Start a vertical run with a Tee at the back of the stove. Other

options are illustrated below.

Preferred Installation – Vertical Vent Through the Roof

This venting configuration allows for the best stove performance. The

vertical pipe promotes natural draft and with the chimney inside the

dwelling, the flue gases stay warm, thus rising at a consistent rate.

Note: See Pages 10 and 11 for Vent Termination Requirements

Clean-Out

Tee

Flashing

Listed Rain Cap

Extend Pipe to the Top

if Existing Chimney is

Corroded or Damaged

Pipe Increaser

Existing

Chimney Pipe

Optional

Clean-Out

Access Door

Optional Complete

Liner and Listed

Termination Cap

Figure 18 - Exterior Vertical Vent

Figure 19 - Vertical Vent Into a Masonry Flue

Figure 20 -

Vertical Vent Through the Roof

Figure 21 -

Interior Vertical Vent into an Existing Class A Chimney

Listed Rain Cap

Listed Rain Cap

Listed Rain Cap

Maintain clearances

specified by vent

manufacturer

Maintain clearances

specified by vent

manufacturer

Maintain clearances

specified by vent

manufacturer

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE