Lennox Hearth MODEL MONTAGE 32FS User Manual
Page 26
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
6
Flue Size
3” (76 mm) Rear
Floor Protection
Front and Sides: 6”(15 mm)
Requirements
Back: Up to 6”(15 mm)
u
Hopper Capacity
55 Lbs.
v
Burn time
15 - 37 hours
v
Fuse, Control Board
5 Amp, 50 volt, 3AG
w
Fuse, Igniter
6 Amp, 15 volt
w
Heat Input
13,000 - 3,000 BTU/hr
v
(BTU’s per hour)
Emissions
< 4.03 gr/hr EPA Certified
Efficiency
8%
Convection (room air)
Blower
150 CFM; 1.5 Amps,
175 rpm
Combustion Blower
95 CFM: 1.0 Amps,
3000 rpm
Auger Motor
1.5 RPM; .48 Amps
Standard Features
Fastfire™ Self Igniter
Wall Thermostat
(wire included)
SPECIFICATIONS - Montage™ 3FS
Notes:
• Dimensions shown are approximations only
.25
(+/- 1/4”)
• Approved for Manufactured Home Installations.
•
Optional Kits Available - Decorative trim kits, log
set, window screen and 3" and 4” Quick Discon-
nect kits.
• The burn grate is designed with advanced
UltraGrate™ technology.
u
In Canada floor protection is required directly
underneath and 2" from the sides of the flue or
chimney adapter. This is recommended in the
US.
v
Burn times, hopper capacity and BTU input
may vary depending on the size and type of fuel
used.
w
Fuses are rated as fast acting.
Product Reference Information
Cat. No.
Model
Ship. Weight
Ship. Volume
H6839
Montage 3FS
85 lb.
.06 cu. ft.
9-5/8”
245mm
28-11/16”
729mm
9-3/16”
233mm
24-11/16”
627mm
1-9/16”
40mm
11-1/4”
286mm
23-1/8”
507mm
2-15/16”
75mm
5-1/2”
140mm
11-1/4”
286mm
7”
178mm
22-1/2”
572mm
2”
51mm
Stove Back
Clean-Out
Tee
5-7/8"
Combustion
Air Inlet
Flue Outlet