37
COMMAND OVERVIEW FOR TV FREQUENCY ENTRY
Switch to desired TV reception
Channel/frequency
switch
...
Enter
frequency
Confi rm entry
and
Change frequency in intervals
or
Example
To enter the frequency 175.25 MHz:
Press
(calling up the frequency menu)
Then
(frequency entry)
LC display:
• Frequency: 175.25 MHz
• Level: 65.0 dBµV
• Operating mode: Analogue cable TV
TV MEASUREMENT
After calling up the frequency menu for the fi rst time you have to
enter the digit order for another frequency entry.
The most recent frequency setting remains even after you switch
the MSK 125 off if it has been entered with digits and confi rmed by
pressing
.
Note
“CABLE ANALOGUE” LEVEL MEASUREMENT
After you have set a channel or frequency the level is measured
automatically and indicated on the LC display in dBµV or dBmV
(depending on the device confi guration). The input level can be
measured in the range of 30 dBµV to 120 dBµV (-30 dBmV to
60 dBmV).
LC display:
• Channel: CH 05
• Operating mode: Analogue cable TV
• Measured level: 86.5 dBµV
Please note that the points before and after the channel number
refer to the precisely set channel:
CH: .10. or CH: S.04.
If you enter the frequency outside the valid channel raster, the
channel is displayed without points:
CH: 10 or CH: S 04