GETTING STARTED

BATTERY OPERATION

Before operating the device for the fi rst time remove the T 8.0 A
fuse from the packaging and place it in the fuse holder.
This fuse prevents the device from being switched on accidentally
during transportation.

After the fuse has been inserted the charging status display does
not function properly until the battery has been fully discharged
once.
Battery operation is only possible if the battery is charged suffi ciently.
Otherwise the MSK 125 cannot be switched on.

Note

Once the battery has fully discharged it must be recharged
immediately to avoid damage to the battery.
Charging starts automatically after the device has been connected
to the mains. The battery cannot overcharge thanks to a protection
switch.

Battery operation is signalled by a red LED next to the

button.
The battery capacity is 6.45 Ah.

Press the

button to check the charging status of the lithium-

ion battery.
The LC display indicates the following values:
• LNB or remote feeding voltage: 14.0 V
• LNB or remote feeding amperage: 255 mA
• 22 kHz switch on
• Battery charging status: 80 %
• Bar graph (8 x 10 %)

Press the

button again to exit this operating mode.