beautypg.com

Auto resample through ifx – KORG TRITON STUDIO V2 User Manual

Page 64

background image

59

Disk

Global

Sampling

Combination

Program

Other functionality

If “Save to” is set to DISK, you can use the page menu
command “Select Directory” (0–1N

☞PG p.96) to spec-

ify the save-destination for the WAVE file that will be
created by sampling.

Sampling

8

Press the SAMPLING [REC] key and then the SAM-
PLING [START/STOP] key

.

9

Play the instrument etc. that is connected to the AUDIO
INPUT jack you specified in “Source Audio.”

0

When you are finished playing, press the SAMPLING
[START/STOP] key

.

Listen to the sampled data

• If you selected “Save to: RAM,” play the C2 key to hear

the sample.

• If you selected “Save to: DISK,” use the page menu

command “Select Directory” (0–1N

☞PG p.96) to hear

the sample.

3. Auto Resample through IFX

This automatically makes the appropriate settings for auto
resampling through the insert effects (IFX).

Setup

1

Select “Auto Sampling Setup” to open the dialog box.

2

Use the radio buttons to select Auto Resample through
IFX

.

3

Use “IFX” to select the insert effect that you want to use
for auto resampling.

4

Press the OK button to execute “Auto Sampling Setup.”
If you decide not to execute, press the Cancel button.
(For the automatically-set parameters and their values,
☞p.60. For examples of using the automatically-set
parameters, refer to

☞BG p.107)

Resample

5

Specify the Key assigned to the sample that you want to
resample. (

☞PG p.98)

6

Make settings for the insert effect. To check the sound,
press the key that you specified in Key.

7

Press the SAMPLING [REC] key and then the SAM-
PLING [START/STOP] key

.

The sample will automatically play back, and resampling
will begin. When the sample finishes playing, resampling
will also end.

Check the resampled data

• Play the key you specified in Key.

To prevent the insert effect from being applied “in
duplicate” when you listen to the resampled data, “BUS
(IFX) Select” (P8 8–1b

☞PG p.122) will automatically be

set to L/R when resampling ends. If you want to apply
IFX and resample once again, you will need to change
this setting back to the same IFX.

Use “Bank” (0–1c

☞PG p.90) to specify the sampling-

destination sample memory (RAM).

Add the contents of “0–1O: Auto Sampling Setup” to the
explanation in “Parameter Guide” 0–1 Recording Page Menu
Command (

PG p.92).