beautypg.com

Kenwood TM-D700 E User Manual

Page 55

background image

49

9

1 Press [MNU] to enter Menu mode.

2 Press [

c

c

c

c

c

]/ [

d

d

d

d

d

] to select “RADIO (1–)”, then press

[OK].

3 Press [

c

c

c

c

c

]/ [

d

d

d

d

d

] to select “AUX (1–9–)”, then press

[OK].

4 Press [

c

c

c

c

c

]/ [

d

d

d

d

d

] to select “SCAN RESUME (1–9–1)”,

then press [OK].

5 Press [

c

c

c

c

c

]/ [

d

d

d

d

d

] to select Time-Operated (default),

Carrier-Operated, or Seek.

6 Press [OK] to complete the setting.

7 Press [MNU] to exit Menu mode.

SELECTING SCAN RESUME METHOD

The transceiver stops scanning at a frequency (or
memory channel) on which a signal is detected. It then
continues scanning according to which resume mode
you select. You can choose one of the following modes.
The default is Time-operated mode.

Time-Operated mode

The transceiver remains on a busy frequency (or
memory channel) for approximately 5 seconds, and
then continues to scan even if the signal is still
present.

Carrier-Operated mode

The transceiver remains on a busy frequency (or
memory channel) until the signal drops out. There is
a 2 second delay between signal drop-out and scan
resumption.

Seek mode

The transceiver remains on a busy frequency (or
memory channel) even after the signal drops out and
does not automatically resume scanning.

Note: To temporarily stop scanning and monitor weak signals, press the
Mic PF key assigned the Monitor function {page 62}. Press the PF key
again to resume scanning.