Unit 4: Operation

SATO M5900RVe Operator Manual

PN 9001125A

Page 4-15

NON-STANDARD CLEAR MODE

Returns non standard protocol code to the default value. The default values are STX (7B), ETX
(7D), ESC (5E), ENQ (40), NUL (7E), CAN (21), OFFLINE (5D). Follow the sequences in th flow
chart below to perform this function.

Figure 4-9, Non-Standard Clear Mode

ALT. PROTOCOL

DEFAULT COMPLETE

DSW2-7 = ON

LINE + FEED

+ POWER

Printer emits

I long and

3 short

beeps.

POWER = OFF
DSW2-7 = OFF