beautypg.com

SATO M5900RVe User Manual

Page 27

background image

Unit 4: Operation

SATO M5900RVe Operator Manual

PN 9001125A

Page 4-3

DSW1 DEFAULT SETTINGS

1-1

1-2

1-3

1-4

1-5

1-6

1-7

1-8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

DSW1 CONFIGURATION

1-1

Data BIt

OFF

8 Data Bit

ON

7 Data Bit

1-2
1-3

Parity

1-2

1-3

ON

ON

Reserved

ON

OFF

Odd

OFF

ON

Even

OFF

OFF

None

1-4

Stop Bit

OFF

1 Stop Bit

ON

2 Stop Bit

1-5
1-6

Baud Rate

1-5

1-6

ON

ON

Normal: 2400, High Speed: 57600

ON

OFF

Normal: 4800, High Speed: 38400

OFF

ON

Normal: 19200, High Speed: 19200

OFF

OFF

Normal: 9600, High Speed: 9600

1-7
1-8

Protocol

1-7

1-8

ON

ON

Status 4

ON

OFF

Status 3

OFF

ON

XOn / XOff

OFF

OFF

Ready / Busy

DSW1 FUNCTION DESCRIPTIONS

FUNCTION

DESCRIPTION

Data Bit

Sets the printer to receive either 7 or 8 bits of data for each byte
transmitted.

Parity

Selects the type of parity used for error detection.

Stop Bit

Selects the number of stop bits to end each byte transmission.

Baud Rate

Select the data rate (bps) for the RS232 port.

Protocol

Selects the flow control and status reporting protocols.