Instructions for the installer

82

4.3 Burner and nozzle characteristics table (80/90 cm. model);

Burner

Rated heating

capacity (kW)

LIQUID GAS – G30/G31 28/37 mbar

Nozzle

diameter 1/

100 mm

By-pass

1/100

mm

Reduced

capacity

(W)

Capacity

g/h G30

Capacity

g/h G31

Auxiliary

1.05

50

30

400

76

75

Semi rapid

1.8

65

33

500

131

129

Rapid

3.0

85

45

800

218

214

Ultra-rapid

4.0

100

65

1600

291

286

Maxi oven

4.6* / 5.2**

106* / 110**

62

1300

378

371

Burner

Rated heating

capacity

(kW)

TOWN GAS – G110 8 mbar

Nozzle

diameter

1/100 mm

Reduced

capacity

(W)

Auxiliary

1.05

145 (/8)

400

Semi rapid

1.8

185 (/2)

500

Rapid

3.0

260 (/3)

800

Ultra-rapid

4.0

350 (/13)

1200

The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.

Burner

Rated heating

capacity

(kW)

NATURAL GAS – G20/G25 20/25 mbar

Nozzle

diameter

1/100 mm

Reduced

capacity

(W)

Auxiliary

1.05

72

400

Semi rapid

1.8

97

500

Rapid

3.0

115

800

Ultra-rapid

4.0

135

1500

Maxi oven

4.6* / 5.2**

155* / 164**

1300

* 80 cm oven / ** 90 cm oven