beautypg.com

Instructions for the installer – Smeg C6GVXI User Manual

Page 10

background image

Instructions for the installer

81

4.2 Burner and nozzle characteristics table (60/70 cm. model);

Burner

Rated heating

capacity (kW)

LIQUID GAS – G30/G31 28/37 mbar

Nozzle

diameter 1/

100 mm

By-pass

1/100

mm

Reduced

capacity

(W)

Capacity

g/h G30

Capacity

g/h G31

Auxiliary

1.05

50

30

400

76

75

Semi rapid

1.8

65

33

500

131

129

Ultra-rapid

4.0

100

65

1600

290

286

Oven

3.2

87

50

900

233

229

Burner

Rated heating

capacity

(kW)

TOWN GAS – G110 8 mbar

Nozzle

diameter

1/100 mm

Reduced

capacity

(W)

Auxiliary

1.05

145 (/8)

400

Semi rapid

1.8

185 (/2)

500

Ultra-rapid

4.0

350 (/13)

1200

Oven

3.2

270

900

The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.

Burner

Rated heating

capacity

(kW)

NATURAL GAS – G20/G25 20/25 mbar

Nozzle

diameter

1/100 mm

Reduced

capacity

(W)

Auxiliary

1.05

72 (X)

400

Semi rapid

1.8

97 (Z)

500

Ultra-rapid

4.0

135 (K)

1600

Oven

3.2

130

900