This function provides the following options in the cooling

fans’ operation when the projector is turned off (p.20).

L 1 ..... Normal operation

L 2 ..... Slower, lower-sound and longish-time than the

normal operation (

L1).

Setting

Fan control

This function is used to display the cumulative lamp

operating time and reset the lamp counter.

When the total lighting time of a lamp exceeds the

recommended total hours of use, the Lamp replacement

icon (Fig.1) will appear on the screen, indicating that the end

of lamp life is reached.

When replacing the projection lamp, reset lamp counter.

See "Resetting the Lamp Counter" on page 64.

Lamp counter

This icon appears on the screen when the end of

lamp life is reached.

Fig .1 Lamp replacement icon

Note:

At turning on, the icon (Fig.1) will appear.

Choose the running speed of cooling fans from the following

options according to the ground elevation under which you

use the projector.

Off ........... Normal speed. Set this function to Off when

using the projector in non-high altitude

environment.

On 1 ........ Faster than Off mode. Select this mode when

using the projector in high altitudes (about

1,200 meters or more above the sea level)

where the fans have less cooling effect.

On 2 ........ Faster than On 1 mode. Select this mode

when using the projector in higher altitudes

than above where the fans have lesser cooling

effect.

Note:

• Fan noise becomes louder in

On 1 and On 2.

• Failure to set the running speed of cooling

fans properly may affect the projector life.

When you want to make a digital processing of a projected

image faster, set this function.

Use the Point ▲▼ buttons, select an item of

Off or On.

Fan

Video delay control

Note:

The Lamp replacement icon (Fig.1) will not appear

when the Display function is set to

Off (p.46), or Freeze

(p.25), or

No show (p.26).

Note:

Noise reduction and Progressive can

not be selected when Video delay control

function is set to

On.