2) deleting a machine from the master list – Sharp UP-820F User Manual
Page 43
41
• The terminal numbers and machine numbers of the master and satellites must be entered into
the master list for IRC communications.
• The terminal numbers and machine numbers of up to 32 machines (one master and 31
satellites) can be entered into the master list.
• The terminal number should be in the range from 1 to 254 and the machine number from 1 to
999999.
• No satellite can perform inline communications unless its terminal and machine numbers are
present in the master list.
• If a machine number which already exists in the master list is entered, an entry error will occur
even when the corresponding terminal number does not exist in the list.
• Even if a set of terminal and machine numbers that exists in the master list is entered, no error
will occur (the list will remain unchanged.)
(2) Deleting a machine from the master list
To delete a terminal number from the master list, proceed as follows:
1. Enter the PGM2 mode from the mode selection window.
2. Select “SETTING” in the PGM2 mode and press the
e
key. The SETTING window will appear.
3. Select “INLINE CONFIG” and press the
e
key. The INLINE CONFIG window will appear.
4. Press the
c
key. The MASTER LIST window will appear.
5. Enter the terminal number to be deleted and press the
D
key.
6. The machine will ask you as follows: “ARE YOU SURE?” If you are sure to delete it, select “YES.”
If not, select “NO.”
7. Press the
c
key to complete the master list.
• You can delete any of the terminal numbers that are in the master list.
• Deleting the master from the master list will inhibit all requests of the satellites from being sent.
NOTE