Programmer's guide pcos series 150 control codes – Star Micronics 150 User Manual
Page 77
Programmer's Guide
PcOS Series 150
Control Codes
Printer Status Set/Inquire
12/14/99
Rev G
Page 67
Function
Inquire printer ID
ASCII
[ENQ] <21>
Hexadecimal
05H 15H
Decimal
<5> <21>
Function
Returns printer IEEE 1284 ID string
Serial/Parallel, IEEE1284
Parallel, non-IEEE 1284
Response
[ACK] <21>
Not supported via PE
Where
<21> is the echo of the command ID.
{ID string} is the IEEE 1284 ID return string, which is as follows:
MFG:Ithaca-Periph.;
CMD:M150CL,IPCL;
CLS:PRINTER;
MDL:S150 PcOS;
DES:Ithaca-Peripherals Series 150;
REV:01.00;
OPTS:$51xy
Where x is a bit field defined as follows:
Bit 0 = Alternate print zone
Bit 1 = 0 not defined
Bit 2 = 0 not defined
Bit 3 = Always 0
Bit 4 = Always 1
Bit 5 = Always 1
Bit 6 = Always 0
Bit 7 = Always 0
and y is a bit field defined as follows:
Bit 0 = Slip capability
Bit 1 = Knife installed
Bit 2 = MICR installed
Bit 3 = Always 0
Bit 4 = Always 1
Bit 5 = Always 1
Bit 6 = Always 0
Bit 7 = Always 0