Programmer's guide pcos series 150 control codes, Validation operation control – Star Micronics 150 User Manual
Page 63

Programmer's Guide
PcOS Series 150
Control Codes
Validation Operation
12/14/99
Rev G
Page 53
Validation Operation Control
The Series 150 Printer has several features that can be altered during operation. For example, the
time delay between when a form is sensed and when the form clamp is activated can be changed.
This allows the operation of the printer to be tailored to the application and the form being used.
All feature control commands are extensions of the [ESC] [EM] sequence. They are defined as
follows.
Function
Validation clamp delay
ASCII
[ESC] [EM] C
Hexadecimal
1BH 19H 43H
Decimal
<27> <25> <67>
IPCL
&%ZC 1 > 2 > EPOS [ESC] f Description This command sets the clamp delay which is the time between when the Where 0 = 0 ms Note: Once issued, the value will be used until the printer is power cycled Function Set validation time-out ASCII [ESC] [EM] V Hexadecimal 1BH 19H 56H Decimal <27> <25> <86> IPCL &%ZV 1 > 2 > EPOS [ESC] f Description This command sets the time-out after a top validation command with Where
form is sensed and when it is clamped. (Only the least four bits are used.)
The default is configurable.
1 = 50 ms
2 = 150 ms, and so on until
15 = 750 ms
or the command is reissued.
autosense is issued and the printer returns to receipt mode.
minute; maximum is 15 minutes. If
(waits forever). The default is configurable.