PLC-XE33 Basic Serial Command Specifications
21/22
information of temperature anomaly is canceled and normal operation is executed.
“24” [CR]
Status: Processing Power Save / Cooling Down
Power management function in Setting menu works and the status goes to Power Save
/ Cooling Down.
During this time, Functional Execution Commands are invalid (not executed).
This status moves to Power Save at set hours after the operation of Cooling Down.
Status
No signal
Power Save / Cooling Down Power Save
Response
“00”
“24”
“04”
5 minutes with no signal After about 90 sec.
“04” [CR]
Status: Power Save
This shows that it moves to Power Save status by Power management function in
Setting menu.
“21” [CR]
Status: Cooling Down in process after turned off due to lamp failure
When a projector is turned off because of lamp failure, it automatically starts Cooling
Down operation, in which the projector returns “21” [CR].
“81” CR
Status: Standby after Cooling Down due to lamp failure
This value is returned when Cooling Down operation due to lamp failure has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts.
7.5. Input Mode Read Command
Command “CR1” [CR]
Detail
Get the selected Input No.
Response
Acceptable
“%1” [CR]
%1
”1” = Computer 1 is selected
”2” = Computer 2 is selected
“3” = Video is selected
Unacceptable “?” [CR]
7.6. Lamp Time Read Command
Command “CR3” [CR]
Detail
Get the total lamp running hours (Not actual lamp used hour, but Eco mode
corresponding value).
Response
Acceptable
“%1” [CR]
%1
Shows the time period with 5 digits numbers.
Example “00410”[CR]
shows 410 hours
Unacceptable “?” [CR]