Sanyo PLC-XE33 User Manual
Page 20

PLC-XE33 Basic Serial Command Specifications
19/22
7. Status Read Command
7.1. Format
7.1.1.
PC issues commands in format as below;
“CR” Command [CR]
Command
1 character
See Basic Status Read Command Table
7.1.2.
When a projector receives the appropriate command, it returns a character line as the
required data.
Required Data [CR]
Required Data
A character line
See Basic Status Read Command Table
7.1.3.
When the received data cannot be decoded, the projector returns “?” [CR].
7.2. Transfer Example
Get input mode for projector with basic commands
Command
issues a command of getting current input mode
PC
→ Projector
“C” “R” “1” “CR”
Projector
→ PC
“1” “CR”
Processing Response
(A few ms
1s)
Shows Computer 1 is selected
7.3. Operation Requirements
When Eco mode is selected in Standby mode of Setting menu and projector is in Standby, Status
Read Commands are invalid.
7.4. Status Read Command
Command “CR0” [CR]
Detail
Get the projector’s operating status
Response
Acceptable
“%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Temperature Anomaly
“88” = Coming back after Temperature Anomaly
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down is in process after Power off due to lamp
failure
“81” = Standby after Cooling Down due to lamp failure
Unacceptable “?” [CR]