beautypg.com

Sanyo PLC-XE33 User Manual

Page 11

background image

PLC-XE33 Basic Serial Command Specifications

10/22

6.5. POWER ON Command

Command “C00” [CR]

Detail

Power ON
When already Power is ON, nothing is done.
When sending this command during processing Countdown, Countdown is
terminated.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.6. POWER OFF Command Quick Power OFF

Command “C01” [CR]

Detail

Power OFF (Standby)

When Power is OFF with ON/STAND-BY button of the projector and remote
control, “Power OFF?” is displayed. However, as soon as this command is sent,
Quick Power OFF is executed.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.7. POWER OFF Command

Command “C02” [CR]

Detail

Power OFF (Standby).

The command operates the same Power OFF function as ON/STAND-BY button
of the projector and remote control.
Once this command is sent, “Power OFF?” is displayed. If this command is sent
again while it is displayed, Power OFF is executed.
When sending this command during Countdown, Countdown is terminated.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.8. Computer 1 Command

Command “C05” [CR]

Detail

Select Computer 1 Input
Although projector returns “OK”, Input search is not executed with this command
while Input search is set to On1 or On2,

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.9. Computer 2 Command

Command “C06” [CR]

Detail

Select Computer2 Input
Note 1) Although projector returns “OK”, Input search is not executed with this
command while Input search is set to On1 or On2,

Note 2)

Although projector returns “OK”, this command is not executed while

Monitor out is selected in Terminal menu,

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]