Control terminals
5
VIDEO OUT terminal (BNC plug)
This terminal is used to connect the camera to a
component such as a monitor or camera control
unit.
6
RESET button
Press the RESET button if an abnormality occurs
with the camera. Settings are not changed
when the camera is reset in this way.
7
Warning indicator
•
The warning indicator lights when the
camera power is turned on.
•
It flashes when there is a hard disk error or if
there is a problem with the backup battery.
GND
GND
GND
WARNING
DC13.8V
H
S
1 2 3 4 5 6 7
Terminal
Signal
Input/output voltage
1 H (HOLD-UP)
Alarm switch input signal
2.5 V or higher when alarm switch off/
0.4 V or lower when alarm switch on
2 GND
Alarm switch and suspicion switch ground 0 V
3 S (SUSPICION)
Suspicion switch input signal
2.5 V or higher when suspicion switch off/
0.4 V or lower when suspicion switch on
4 GND
Warning ground
0 V
5 WARNING
Warning signal output
3.3 V or higher when warning generated
6 GND
Power supply ground
0 V
7 DC 13.8 V
Power supply input
13.8 V DC