Seiko Instruments DPU-30 User Manual
Page 78
5-50
DC2 % n
Print Drive User-Define
Code
12
16
+ 25
16
+ n
Domain of
function
1
≤ n ≤ 16
Function
Executes the printing according to the print drive defined by a user.
n = 1 : The amount of 1 × 8 dots
n = 16 : The amount of 16 × 8 dots
Details
• When one line is printed, how many times the line is divided is determined
depending on the amount of n × 8 dots.
Example) Suppose that the number of dots printed
= 128 dots, and n = 1
128
ч (1 Ч 8) = 16 (one line printed is divided into 16 parts)
• The smaller the value of n, the lower the required electric power. And the bigger
the value of n, the faster the speed of printing.
DC2 ~ n
Print Density Set
Code
12
16
+ 7E
16
+ n
Domain of
function
0
≤ n ≤ 255
Function Sets the print density
Details
• n means n %.
• When adjusting the print density double for low heat sensitive paper, set n = 200.
• The print density cannot be set for each character.
• In default, n = 100.