DLE ENQ n
Major Buffers Clear in Real Time
Code
10
16
+ 05
16
+ n
Domain of
function
n
= 1
Function
Clears the major buffers in real time while off line.
n = 1: The major buffers are cleared.
Details
• This command is valid while off line.
• This command is executed at the reception.
• When the real time command is invalid, this command is ignored.
• Users should be aware that even if this command is valid and consistent with
DLE ENQ 1 in the image data, this command will be executed. (however, this
note is not necesary while on line)
• The buffers cleared are:
• Receive buffer
• Print buffer