Seiko Instruments DPU-30 User Manual
Page 66
5-38
9. Bitimage
commands
ESC
∗ m nl nh [d1...dk] Bitimage
Select
Code
1B
16
+ 2A
16
+ m + nl + nh + [d1...dk]
Domain of
function
m
= 0,1,32,33
0
≤ nl ≤ 255
0
≤ nh ≤ 3
0
≤ d ≤ 255
Function Specifies the Bitimages with the number of dots specified as nl and nh in Mode m.
m Mode
The number
of dots in
the vertical
direction
The number of
dots in the
horizontal
direction
(1 line)
The number of
data (k)
0
8 dot single density
8
192
nh × 256 + nl
1
8 dot double density
8
384
nh × 256 + nl
32
24 dot single density
24
192
(nh × 256 + nl) × 3
33
24 dot double density
24
384
(nh × 256 + nl) × 3
Details
• If m is out of the domain of function, the data after nl is processed as the normal
data.
• nl and nh mean the number of dots in the horizontal direction of the Bitimage to
be printed.
• If the dot is specified beyond the printable area, the data is deleted.
• The data deployment position corresponds to the deployment start position.
• This command is affected by the inverse print but the others such as dual print,
bold print and reverse print.
• Refer to the diagram for how to deploy the data.