2 parallel interface, 3 serial interface – Seiko Instruments DPU-30 User Manual

Page 25

background image

4-3

4.2 PARALLEL

INTERFACE


1. Data input timing

T5

T4

T3

T2

T1

DATA0 to 7

BUSY

T6

T7

STROBE

ACK


Min.

Max.

Unit

T1 0.1

µs

T2 0.5

µs

T3 0.5

µs

T4

− 0.5 µs

T5 0

µs

T6 0.5

µs

T7

− 1.0 µs



4.3 SERIAL

INTERFACE


1. Hardware

control

The RTS signal (Low or High) controls the transmission of the data from a host computer.

When the data stored in the input buffer of the printer exceeds 4,046 bytes, the RTS signal turns
Low.
Once the RTS signal turns Low, the host computer stops to transmit the data.
If the data stored in the input buffer of the printer falls below 3,995 bytes, the RTS signal turns
High.
Once the RTS signal turns High, the host computer resumes transmitting the rest of the data.

∗ When the printer fails (for example, paper-out), the RTS signal also turns Low.

And then, after the printer gets back to normal, the RTS signal turns High.