Seiko Instruments DPU-30 User Manual
Page 63

5-35
GS r n Status
Transmit
Code
1D
16
+ 72
16
+ n
Domain of
function
0
≤ n ≤ 255
Function
Returns the current printer status. 
n 
= 
Details
• n is valid only for the least significant bit. 
• Regardless of the validity of the automatic status response, this function returns 
the current status.
• For the status values, refer to Table 5-1 Status Response Value Table. 
• This command is executed at the deployment of the receive buffer so that the 
execution of the command may be delayed depending on the conditions of the 
receive buffer. 
• When a value is returned, the conditions of the host machine are not checked.
 
 