beautypg.com

Seiko Instruments DPU-30 User Manual

Page 63

background image

5-35

GS r n Status

Transmit

Code

1D

16

+ 72

16

+ n

Domain of

function

0

≤ n ≤ 255

Function

Returns the current printer status.
n

= B : The status is returned

Details

• n is valid only for the least significant bit.
• Regardless of the validity of the automatic status response, this function returns

the current status.

• For the status values, refer to Table 5-1 Status Response Value Table.
• This command is executed at the deployment of the receive buffer so that the

execution of the command may be delayed depending on the conditions of the
receive buffer.

• When a value is returned, the conditions of the host machine are not checked.