beautypg.com

1 front panel – Sony DVW-250 User Manual

Page 9

background image

2-1 Front Panel

Status indications

Status indication panel

This displays warnings, the tape remaining, the battery
capacity remaining, the operating status, and time

indications.

Status indication panel

The details of these indications are as follows:

Warning indications

The following indications appear in the event of a fault

in the unit:

RF: Recording or playback is not possible because

the video heads are clogged, or there is a fault in
the circuit.

SERVO: The drum servo or capstan servo lock is

lost.

HUMID: There is condensation on the head drum.

Alternatively, the humidity is high.

SLACK: The tape winding is not correct.

For more details, see the section "Warning Indications"

(page A-1).

Operating status indications

These show the operating status of the unit, as follows:

DIAG: in diagnosis mode

PB: when the playback time code is displayed.

VITC: when the time code displayed is the VITC

(Vertical Interval Time Code)

NDF: in non-drop frame mode (DVW-250 only) (see

the footnotes on page 4-9)

EXT-LK: when the time code on this unit is locked

to the time code on an external unit

2FLD: when the internal time code generator is not

color frame locked"

1) Color frame lock

This forces the time code frame number to be even for information in the input video signal and the time code is

the first and second color fields and odd for the third and not locked to an external time code, then in the F-RUN
fourth color fields. When there is color frame mode the color frame lock is automatically applied.

2~4 Chapter 2 Location and Function of Parts

This manual is related to the following products: