2-1 Front Panel

Time code setting controls

VITC switches VITC REC (record) switch

These determine the lines in the vertical blanking

interval in which the VITC" is recorded.

For the DVW-250, the factory default is for switch A
to be in position 6 (line 16) and switch B in position 8
(line 18).
For the DVW-250P, the factory default is for switch A
to be in position C (line 19) and switch B in position E
(line 21).

For details of the relation between the switch positions and

the line numbers, see page 4-10.

This selects whether or not to record the VITC.

ON: Record the VITC.

OFF: Do not record the VITC.

1) VITC (Vertical Interval Time Code)

This time code signal is inserted in two lines of the

vertical blanking interval. This allows the time code to
be read even at very slow playback speeds.