beautypg.com

4. control codes used for peripheral units, 5. auto cutter control (sp240 type only), 6. other control codes – Star Micronics SP200F SERIES User Manual

Page 23

background image

– 20 –

ENGLISH

6-4. Control Codes Used for Peripheral Units

Control codes

Hexadecimal codes

Function

n1 n2

1B 07 n1 n2

Adjust drive pulse width for peripheral unit (Default
setting)

07

Deferred drive command “A” for peripheral unit 1

1C

Immediate drive command “B” for peripheral unit 1

6-5. Auto Cutter Control (SP240 type only)

Control codes

Hexadecimal codes

Function

“d” “0”

1B 64 30

Full-cut command to the auto cutter

“d” <0>

1B 64 00

“d” “1”

1B 64 31

Partial-cut command to the auto cutter

“d” <1>

1B 64 01

“d” “2”

1B 64 32

Full-cut command to the auto cutter

“d” <2>

1B 64 02

after paper feed

“d” “3”

1B 64 33

Partial-cut command to the auto cutter after paper

“d” <3>

1B 64 03

feed

6-6. Other Control Codes

Control codes

Hexadecimal codes

Function

18

Cancel print data in buffer

*

1

05

Enquiry

*

1

11

Set select mode

*

1

13

Deselect printer

“@”

1B 40

Initialize printer

“e” “0”

1B 65 30

ON LINE/FEED switch valid

“e” <0>

1B 65 00

(Default setting)

“e” “1”

1B 65 31

ON LINE/FEED switch invalid

“e” <1>

1B 65 01

“f” “0”

1B 66 30

ON LINE switch valid

“f” <0>

1B 66 00

(Default setting)

“f” “1”

1B 66 31

ON LINE switch invalid

“f” <1>

1B 66 01

*

1

: Valid for the RS-422A only.