2 burner and nozzle characteristics table, Burner, Rated heating capacity – Smeg CS150SA User Manual

Page 9: Lpg - g30/g31 28/37 mbar, Drawing ref. x238), Nozzle diameter, 1/100 mm, By-pass, Reduced flowrate, Flowrate

background image

11

Instructions for the Installer

3.2

Burner and nozzle characteristics table

Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

(drawing ref. X238)

Nozzle

diameter

1/100 mm

By-pass

Mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1.05

50

30

400

76

75

Semi rapid

1.8

65

33

500

131

129

Rapid

3.0

85

45

800

218

215

Fish Burner

1.9

68

45

800

138

136

Ultra rapid

4.0

100

65

1600

291

286

UR2 Inner ring

1.0

46

30

400

73

71

UR2 Outer ring

3.6

68+68

65

1600

284

250

Burner

Rated

heating

capacity

(kW)

NATURAL GAS – G20 20 mbar

Nozzle diameter

1/100 mm

Drawing

Ref.

Reduced flowrate

(W)

Auxiliary

1.05

72

(X)

400

Semi rapid

1.8

97

(Z)

500

Rapid

3.0

115

(Y)

800

Fish Burner

1.9

94

(X)

800

Ultra rapid

4.0

135

(K)

1600

UR2 Inner ring

1.0

70

(X)

400

UR2 Outer ring

3.6

102 +102

(Z)

1600

3.3

Hob burner layout

BURNERS

1

Auxiliary

2

Semi rapid

3

Rapid

4

WOK

5